top of page

Float Operated Level Transmitters

A simple and reliable sensor for continuous level indication and control of any liquid chemically compatible with the (sensor) material, unaffected by electrical conductivity, temperature, pressure or viscosity. The float is designed for variety of liquidsand its unique self-cleaning construction which is well suited for sticky or dirty environment with no float hang-ups.

Product Variants

MLX Series - Magnetostrictive Level Transmitter

FLX Series - Reed Chain Level Transmitter 

  • Continous ‘Float Type’ Analog Sensor, resistive to most liquids

  • Pre calibrated at factory - No Field Calibration required

  • 4-20mA or 4-20mA with HART or RS-485

  • High Resolution & Repeatability

  • Liquid level or liquid / liquid interface detection

  • Multiple alarm relays adjustable option

  • Customized lengths up to 4 meters

  • Intrinsically safe option available

Applications
  • Water

  • Milk

  • Fruit juice

  • Effluents

  • Sump

  • Phosphate

  • Sludge coolant

  • Sulphuric acid

  • Caustic

  • Reservoir Control

  • Cooling Towers

  • Waste water & sewage treatment plants

Reed Chain Level Transmitters – FLX

It consists of a float & guide stem assembly in non-magnetic material to achieve undisturbed flux. A chain of closely spaced glass encapsulated reed switches & resistors are placed inside the guide tube. During rise and fall of liquid level, the float moves & actuates a series of reed switches in the chain, through a magnet system within it and develops a proportional resistance. The operation is similar to a sliding resistance potentiometer. The sensed resistance is fed to the transmitter located in the enclosure for conversion to a signal of 4-20mA.

Specifications

Measuring Range:  ² GSL - (Top ¹ DB + Bottom ¹ DB)

Span (L):   Min. 300 mm (² GSL 400 mm), Max. 3850 mm (² GSL 4000 mm)

Resolution / Accuracy:  Standard ±10 mm /1 mm, High ± 5 mm / 0.5 mm

Installation:

  1. Top of the tank

  2. Top mount with stilling well

  3. Mounting into the external chamber

  4. Mounting to MLI chamber

 

Enclosure:

  1. Weather Proof IP-67

  2. Ex-Proof IP-66, Gr IIA,IIB or IIC

 

Conduit Connection:

  1. Brass Double Compression Gland

  2. PG gland

 

Wetted Parts: Probe/Stem: SS304, SS316, SS316L, SS316 with PTFE Sleeve SS304, SS316, SS316L, PP, PVDF

Float:  Ø41mm, Ø45mm, and Ø63mm in SS316 and Ø46mm, Ø48mm in PP/PVDF

Process Connection:  Flanged / Threaded

Output: DC 4-20mA (Isolated) or 1-5 VDC or 2-10VDC or 4-20mA with HART or RS-485

Wiring System:  Wiring System

Max. Temperature:  120°C (For Metallic MOC)

Max. Test pressure: 10Kg/cm2 (Metallic MOC)

Special feature: Intrinsically Safe, Explosion Proof IP-66 Ex ia, Gr IIA,IIB

¹ DB - Dead Band, ² GSL - Guided Stem Length

Downloads